(121) Page » Technical Parameters – Nuclear Reactor

Type of reactor WWER 440 / V230 Reactor's thermal output 1,375 MWt Coolant and Moderator demineralized water Reactor's pressure vessel Sizes - diameter 3,840 mm - ...

(122) Page » Technical Parameters – Steam Generator

Number of steam generators per unit 6 Inner sizes - length 11,800 mm - diameter 3,210 mm Weight 145 t Steam output 452 t/h Steam pressure 4.6 MPa Steam temperature 256 °C Temperature of feeding water 158–223 °C Number of heat exchange pipes 5,536 Heat exchange surface 2,510 m2

(123) Page » Technical Parameters – Turbo Generator

Number of TGs per unit 2 Nominal output 220 MW Revolutions 3,000 rev/min Steam temperature (HP part) 256 °C Steam pressure (HP part) 4.

(124) Page » Technical Parameters – Vitrification Facility

Waste specific activity 109 -1010 Bq.dm-3 Main RA-nuclides and compounds Cs, Sr, Pu, K2CrO4 Evaporator's heating temperature 128–140 °C Melting vessel of vitrification furnace Inconel Furnace operational temperature max.

(125) Page » Technical Parameters – Vitrification Facility

Basic Technical Specifications: 109 -1010 Bq.dm-3 Cs, Sr, Pu, K2CrO4 Evaporator's heating temperature 128-140°C Melting vessel of vitrification furnace Inconel Furnace operational temperature max.

(126) Page » Technological Plan for the Operation Termination

the transport of all reactor fuels to storage pools, the cooling down of fuel cells in storage pools, the draining and processing of all operational media from unnecessary equipment, the processing ...

(127) Page » Technologies for separation, fragmentation and decontamination of metallic RAW

A specialized workstation has been constructed to deal with the metallic materials from the former A1 NPP powerhouse. Metallic RAW is sorted according to intensity of contamination and according to the type of metallic RAW: carbon metals, high-grade steel and colored metals.

(128) Page » Technologies for treatment of used air-conditioning filters and used electric cabels

Processing of used HVAC filters Technology for processing of HVAC (heat, ventilation and air-conditioning) filters from the HVAC systems of nuclear power plants is used in facility that crushes filters, separates magnetic and aluminium fragments from the crushed material, feeds and mixes chemicals to the crushed material.

(129) Page » Technology

The V1 Nuclear Power Plant with its WWER 440 type reactors was conceptually designed as two independent energy units. The technological design was double circuited.   Primary circuit The primary circuit is that part of NPP facilities, where nuclear energy is transformed into thermal energy.

(130) Page » Technology

The A1 Nuclear Power Plant with its KS 150 heterogeneous reactor was designed to have an electrical output of 143 MW. Natural metallic uranium was used as fuel, heavy water was moderator and carbon dioxide was used for cooling.