Technical Parameters of BRWTC

Evaporator 
Type of facility continuous flow
Operation continuous – campaign
Heating medium steam, p = 0.5 MPa
Heating temperature 105–108 °C
Heat exchange surface 9.6 m2
Output 300-400 dm3/h
Decontamination factor 104
   

Cementation
 
Operation discontinuous
FCC volume 3.0 m3
Sloping mixer volume
0.5 m3
Output 1–2 FCC per shift
   

High-pressure press
 
Press force 20,000 kN
Volume reduction factor 4–8
Output max. 10 barrels per hour
Press product containment barrel 200 dm3
   

Incinerator
 
Operation continuous – campaign
Output 50 kg/h – solid RAW
  30/10/10 kg/h – solid/liquid/ionex
Combustion temperature, stage I 750–850 °C
Combustion temperature, stage II 1,000–1,200 °C
Amount of ash max. 4 kg / h
Volume reduction factor 80–150
Decontamination factor 105–107
V1 NPP Decommissioning A1 NPP Decommissioning Spent Nuclear Fuel Management Management of Institutional Radioactive Waste and Captured Radioactive Materials RAW Management Transport of RAW and SNF Commercial activities